Latest Installation Standard in the US, Europe, and Australia
SGS certified pressure resistance of up to 61kg/cm² (870psi) !
Traditionally refrigerant copper tubes are connected using welding or flaring, both time-consuming and complex.
With Y-Tech Push Fit Connectors, simply push the tube in for a fast and secure connection — no extra tools required.
Trusted by Frontline Users
Repeat purchases and lasting loyalty built on genuine quality
Y-Tech Push Fit Connectors have been widely adopted by HVAC contractors, appliance retailers, and air conditioning service companies across Asia. With thousands of units sold, our products have earned strong trust across industries and applications.
- 漢民科技股份有限公司
- 九億冷凍空調有限公司
- 聯碩電器股份有限公司
- 儷佳空調工程有限公司
- 允赫科技工程有限公司
- 元榮電器有限公司
- 元鑫空調工程有限公司
- 冠允空調工程有限公司
- 冠鎰工程行
- 冷氣家節能科技有限公司
- 合興電器行
- 合豐電器行
- 和翼冷氣工程行
- 安毅空調工程行
- 熊詠鑫冷氣工程有限公司
- 展碁精密有限公司
- 席源興業有限公司
- 弘年空調工程有限公司
- 承泓冷氣空調有限公司
- 權城冷氣工程有限公司…..等
10-Year Quality Warranty
Each connector is manufactured under strict quality control and comes with a 10-year product warranty. If any defect caused by product quality (excluding misuse or natural disasters) occurs during the warranty period, free replacement or repair service will be provided.
* Warranty period is calculated from the shipping date. Y-Tech reserves the right of final interpretation and warranty termination.
Still using dangerous welding methods for air-conditioning installation?
Fire caused by welding during HVAC room installation at the Presidential Office!
Why you should use the Y-Tech Push Fit Connector
Compared with traditional methods, using the Y-Tech Push Fit Connector saves 90% of time and more than 60% of cost.
Scroll for more >>
| Installation Method | Traditional Method (Welding) | Traditional Method (Flare Connection) | Y-Tech Push Fit Connector |
| Disassembly | Impossible | Possible | Possible |
| Open Flame | Required | Not required | Not required |
| Space Requirement | Large (requires allowance for welding tools) | Large (requires allowance for flaring tools and wrenches) | Small
(very suitable for narrow spaces) |
| Time Required | Several minutes to tens of minutes per joint | Several minutes to tens of minutes per joint | 30 seconds |
| Cost | Labor, welding materials, welding tools, gas cylinder | Labor, tools and parts for flaring, torque wrench | Connector only |
| Durability | Depends on welding skill; poor workmanship may cause leakage | Depends on workmanship; poor workmanship may cause leakage | Can last over 10 years if properly installed |
| Safety | Hazardous | Relatively safe | Safe |
No welding or flaring tools required – simply insert to complete copper tube connection.
Applicable Scenarios
1. Connecting new units to existing refrigerant piping
2. Locations where hot work (welding) is not allowed
3. Temporary refrigerant piping connection, e.g., for pipe cleaning
4. High-altitude work, confined spaces, or sites requiring quick installation
* The above is illustration
Applications
Residential air-conditioning, commercial HVAC, convenience store/supermarket freezers, heat pumps, and other refrigerant copper pipe connections.
Compatible refrigerants: R22, R134a, R410A, R507, R600a, R290, R32, R404A, R407A, R407C, R500, R454B, R448A, R449A
Maximum working pressure: 870 psi / 60 bar / 61 kg/cm²
Temperature resistance: -40 ~ 121 ℃
Body materials: corrosion-resistant brass, high-strength engineering plastic, stainless steel, high-performance rubber.
Simply insert into the connector to complete installation quickly after preparing the copper tubes
SGS certified – pressure resistant with no leakage
No leakage under 40 kg/cm² (approx. 570 PSI) as verified by the SGS pressure test report.
Push Fit Connectors have been adopted as the standard installation method in multiple countries
Y-Tech helps you solve problems, not create new ones.
Pressure resistance up to 60 kg/cm² – reliable connections with no leakage!
If you are a refrigeration/air-conditioning technician, connecting copper pipes used to require oxygen-free welding or flaring and threading methods – both time-consuming and labor-intensive.
Refrigerant copper tube Push Fit Connectors, due to their speed, safety, and cost efficiency, have been widely used in Europe, America, and Australia, and have become the standard HVAC installation method in those regions.
Y-Tech refrigerant copper pipe Push Fit Connector is easy to install and user-friendly – simply insert the prepared copper pipe into the connector. It is reusable and a great helper in saving both time and cost.
Not your typical cheap Chineses product – pressure resistance up to 60 kg/cm², with reliable and safe quality.
If you have any questions about installation or usage, feel free to contact us.
Pressure Test
How do you want to connect refrigerant copper tubes?
1. Time-consuming and labor-intensive traditional methods
or
2. Patented technology specially developed and designed for copper pipe connections
Applicable to air-conditioning, freezers, heat pumps, etc.
How to Use the Y-Tech Push Fit Connector
Models, Types, and Specifications
Straight Push Fit Connector
| Model | Tube Diameter | Specifications (mm) | |||
| inch | mm | ØA | B | ØC | |
| PC02 | 1/4″ | 6.35 | 6.65 | 48 | 20 |
| PC03 | 3/8″ | 9.52 | 9.70 | 50 | 24 |
| PC04 | 1/2″ | 12.70 | 13.0 | 54 | 27 |
| PC05 | 5/8″ | 15.88 | 16.2 | 57 | 30 |
| PC06 | 3/4″ | 19.05 | 19.3 | 63.5 | 37 |
| PC07 | 7/8″ | 22.22 | 22.5 | 66.5 | 40 |
| PC09 | 1-1/8″ | 28.58 | 28.9 | 75 | 48 |
Elbow Push Fit Connector
| Model | Tube Diameter | Specifications (mm) | |||
| inch | mm | ØA | B | ØC | |
| PE02 | 1/4″ | 6.35 | 6.65 | 28 | 20 |
| PE03 | 3/8″ | 9.52 | 9.70 | 32 | 24 |
| PE04 | 1/2″ | 12.70 | 13.0 | 36 | 27 |
| PE05 | 5/8″ | 15.88 | 16.2 | 39 | 30 |
| PE06 | 3/4″ | 19.05 | 19.3 | 43 | 37 |
| PE07 | 7/8″ | 22.22 | 22.5 | 45 | 40 |
| PE09 | 1-1/8″ | 28.58 | 28.9 | 53.5 | 48 |
Straight Reducer Push Fit Connector
| Model | Tube Diameter | Specifications (mm) | |||
| inch | mm | ØA | ØB | C | |
| PCR02 | 1/4″ x 3/8″ | 6.35 x 9.52 | 6.65 | 9.7 | 50 |
| PCR03 | 3/8″ x 1/2″ | 9.52 x 12.70 | 9.70 | 13 | 55 |
| PCR04 | 1/2″ x 5/8″ | 12.70 x 15.88 | 13.0 | 16.2 | 60.5 |
Elbow Reducer Push Fit Connector
| Model | Tube Diameter | Specifications (mm) | ||||
| inch | mm | ØA | ØB | C | D | |
| PER02 | 1/4″ x 3/8″ | 6.35 x 9.52 | 6.65 | 9.7 | 28 | 32 |
| PER03 | 3/8″ x 1/2″ | 9.52 x 12.70 | 9.70 | 13.0 | 32 | 36 |
| PER04 | 1/2″ x 5/8″ | 12.70 x 15.88 | 13.0 | 16.2 | 36 | 39 |
Threaded Push Fit Connector
| Model | Tube Diameter | Specifications (mm) | D | Torque (N.m) | |||
| inch | mm | ØA | B | HEX C | |||
| PS02 | 1/4″ | 6.35 | 6.65 | 37 | 17 | 7/16-20 UNF | 18.0 |
| PS03 | 3/8″ | 9.52 | 9.70 | 40 | 22 | 5/8-18 UNF | 32.0 |
| PS04 | 1/2″ | 12.70 | 13.0 | 45 | 24 | 3/4-16 UNF | 49.0 |
| PS05 | 5/8″ | 15.88 | 16.2 | 51.5 | 27 | 7/8-14 UNF | 70.0 |
Tee Push Fit Connector
| Model | Tube Diameter | Specifications (mm) | |||
| inch | mm | ØA | B | C | |
| PT02 | 1/4″ | 6.35 | 6.65 | 56 | 26 |
| PT03 | 3/8″ | 9.52 | 9.70 | 64 | 30 |
| PT04 | 1/2″ | 12.70 | 13.0 | 72 | 34 |
| PT05 | 5/8″ | 15.88 | 16.2 | 78 | 35.5 |
45° Elbow Push Fit Connector
| Model | Tube Diameter | Specifications (mm) | ||
| inch | mm | ØA | B | |
| PD02 | 1/4″ | 6.35 | 6.65 | 28 |
| PD03 | 3/8″ | 9.52 | 9.70 | 32 |
| PD04 | 1/2″ | 12.70 | 13.0 | 36 |
| PD05 | 5/8″ | 15.88 | 16.2 | 39 |
Push Fit Refrigerant Charging Valve
| Model | Tube Diameter | Specifications (mm) | |||
| inch | mm | ØA | B | C | |
| NC02 | 1/4″ | 6.35 | 6.65 | 43.8 | 7/16 20 UNF |
Push Fit Sight Glass Connector
| Model | Tube Diameter | Specifications (mm) | ||||
| inch | mm | ØA | B | ØC | D | |
| PG02 | 1/4″ | 6.35 | 6.65 | 69 | 20 | 24 |
| PG03 | 3/8″ | 9.52 | 9.70 | 69 | 24 | 30 |
| PG04 | 1/2″ | 12.70 | 13.0 | 71 | 27 | 30 |
| PG05 | 5/8″ | 15.88 | 16.2 | 74 | 30 | 30 |
Ball Valve Push Fit Connector
| Model | Tube Diameter | Specifications (mm) | |||||
| inch | mm | A | B | C | D | E | |
| PV02 | 1/4″ | 6.35 | 95 | 26 | 16 | 55 | 20.0 |
| PV03 | 3/8″ | 9.52 | 101 | 26 | 16 | 55 | 20.0 |
| PV04 | 1/2″ | 12.70 | 107 | 26 | 16 | 55 | 20.0 |
| PV05 | 5/8″ | 15.88 | 106 | 28 | 19 | 60 | 20.0 |
| PV06 | 3/4″ | 19.05 | 117 | 28 | 19 | 60 | 20.0 |
| PV07 | 7/8″ | 22.22 | 127 | 41 | 21 | 67 | 32.0 |
Measuring Tool
Measuring Tool
Removal Ring
Frequently Asked Questions (FAQ)
Can Push Fit Connectors be reused?
Push Fit Connectors can withstand adjustments during initial installation, but it is not recommended to reuse connectors that have been in service for years on new piping. Although special tools can be used for disassembly, sealing performance may degrade with repeated removals.
Do refrigerant pipes require special treatment before installing the Push Fit Connector?
Burrs must be removed using a deburring tool, and the pipe edge must be polished with sandpaper (any grit) to avoid sharp edges cutting the internal rubber ring. If the pipe is not perfectly round, it must be reshaped first. If uncertain, please consult our sales staff.
Why is a measuring tool required before installing the Push Fit Connector?
To ensure the refrigerant pipe is fully inserted into the connector to the correct depth, always mark the pipe using the measuring tool beforehand.
After installing the Push Fit Connector, is pressure testing required before charging refrigerant?
Yes, always perform a pressure test first to verify the airtightness of the entire system.
How do I choose the required specifications?
First measure the outer diameter of the pipe to be used and select the appropriate specification. If unsure, consult our sales staff.
Under what circumstances will the Push Fit Connector fail?
Failure may occur if installation procedures are not followed, if unsuitable refrigerants are used, if pressure or temperature exceeds allowable limits, if deformed copper pipes are installed without reshaping, or if the connector is kicked/stepped on causing deformation and gaps.
Can defective Push Fit Connectors be replaced?
Yes. Within ten years from the purchase date, if installation issues are confirmed to be product defects, we will replace the product. Please refer to the replacement policy below.
Ordering and Delivery FAQs
For frequently asked questions regarding ordering and delivery, please click here to view the details.
Push Fit Connector Replacement Policy
Replacement Period
Valid for ten years from the invoice date.
Replacement Coverage
We provide replacement service for product defects. Damage caused by human factors is not covered (e.g., copper pipe edges not deburred causing seal damage, use with non-permitted fluids, excessive pressure/temperature, damage from repeated insertions/removals, etc.).
Replacement Shipping Costs
We will ship the replacement product free of charge to your designated address. Our logistics partner will then collect the defective product – you do not need to pay any shipping costs.
Notes
Once sold, Push Fit Connectors cannot be returned or exchanged except for defective products. Our company reserves the final right of interpretation of the warranty policy.